Three-dimensional printing in integrated multi-modality imaging approach for management of prosthetic valves infective endocarditis

Published: November 24, 2022
Abstract Views: 982
PDF: 257
Video 1: 120
Publisher's note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Authors

After heart failure, infectious endocarditis is the second leading cause of death in patients with prosthetic valves. Aortic pseudoaneurysms are a serious complication of infective endocarditis in mechanical or bioprosthetic aortic prostheses. Diagnostic and management challenges are posed by aortic pseudoaneurysms. In these cases, a multi-modality imaging approach with a heart team is recommended. We described two cases of aortic pseudoaneurysms that developed as a result of infective endocarditis. The first case involved a TAVI patient who developed infective endocarditis as a result of diabetic foot complications. Because traditional echocardiography and computed tomography failed to show the anatomy of the lesion, we used 3D printing to show the anatomy, extension of the pseudoaneurysm, and proximity to the right coronary artery. The second case involved a patient who underwent Bentall's surgery with an aortic root and mechanical aortic valve and later developed infective endocarditis complicated by pseudoaneurysms. In this case, 3D printing was used for preoperative surgical planning.

Dimensions

Altmetric

PlumX Metrics

Downloads

Download data is not yet available.

Citations

Sollini M, Berchiolli R, Bolton RCD, et al. The “3M” approach to cardiovascular infections: Multimodality, multitracers, and multidisciplinary. Semin Nucl Med 2018;48:199–224. DOI: https://doi.org/10.1053/j.semnuclmed.2017.12.003
Glaser N, Jackson V, Holzmann MJ, et al. Prosthetic valve endocarditis after surgical aortic valve replacement. Circulation 2017;136:329–31. DOI: https://doi.org/10.1161/CIRCULATIONAHA.117.028783
Hei C, Tam A, Chan YC, et al. The role of three-dimensional printing in contemporary vascular and endovascular surgery: A systematic review. Ann Vasc Surg 2018;53:243–54. DOI: https://doi.org/10.1016/j.avsg.2018.04.038
Atik FA, Navia JL, Svensson LG, et al. Surgical treatment of pseudoaneurysm of the thoracic aorta. J Thorac Cardiovasc Surg 2006;132:379-385.e1. DOI: https://doi.org/10.1016/j.jtcvs.2006.03.052
Alsomali A, Eltayab A, Aldosari S, et al. Recurrence of left ventricular pseudoaneurysm after multiple mitral valve replacements. Monaldi Arch Chest Dis 2021;92.2043. DOI: https://doi.org/10.4081/monaldi.2021.2043
Cribier A, Eltchaninoff H, Bash A, et al. Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: First human case description. Circulation 2002;106:3006–8. DOI: https://doi.org/10.1161/01.CIR.0000047200.36165.B8
Amat-Santos IJ, Messika-Zeitoun D, Eltchaninoff H, et al. Infective endocarditis after transcatheter aortic valve implantation results from a large multicenter registry. Circulation 2015;131:1566–74. DOI: https://doi.org/10.1161/CIRCULATIONAHA.114.014089
Khan A, Aslam A, Satti KN, Ashiq S. Infective endocarditis post-transcatheter aortic valve implantation (TAVI), microbiological profile and clinical outcomes: A systematic review. PLoS One 2020;15:1–19. DOI: https://doi.org/10.1371/journal.pone.0225077
LeMaire SA, Coselli JS. Options for managing infected ascending aortic grafts. J Thorac Cardiovasc Surg 2007;134:839–43. DOI: https://doi.org/10.1016/j.jtcvs.2007.05.059
Bentall H, De Bono A. A technique for complete replacement of the ascending aorta. Thorax 1968;23:338–9. DOI: https://doi.org/10.1136/thx.23.4.338
Mookhoek A, Korteland NM, Arabkhani B, et al. Bentall procedure: A systematic review and meta-analysis. Ann Thorac Surg 2016;101:1684–9. DOI: https://doi.org/10.1016/j.athoracsur.2015.10.090
Malvindi PG, Van Putte BP, Heijmen RH, et al. Reoperations for aortic false aneurysms after cardiac surgery. Ann Thorac Surg 2010;90:1437–43. DOI: https://doi.org/10.1016/j.athoracsur.2010.06.103
Soutar AK, Naoumova RP. Mechanisms of disease: Genetic causes of familial hypercholesterolemia. Nat Clin Pract Cardiovasc Med 2007;4:214–25. DOI: https://doi.org/10.1038/ncpcardio0836
Otto CM, Nishimura RA, Bonow RO, et al. 2020 ACC/AHA Guideline for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines. Circulation 2021;143:e35-e71. DOI: https://doi.org/10.1161/CIR.0000000000000923
Lindquist EM, Gosnell JM, Khan SK, et al. 3D printing in cardiology: A review of applications and roles for advanced cardiac imaging. Ann 3D Print Med 2021;4:100034. DOI: https://doi.org/10.1016/j.stlm.2021.100034
Henn MC, Mokadam NA. Three-dimensional printing to plan intracardiac operations. JTCVS Tech 2021;9:101–8. DOI: https://doi.org/10.1016/j.xjtc.2021.02.050

How to Cite

Eltayeb, Abdalla, Shahid Khan, Salam Dib, Ali Musthaq, Ahmed Elshaer, Abdullah Shaik, Domenico Galzerano, Bahaa Fadel, Mohamed Aladmawi, and Olga Vriz. 2022. “Three-Dimensional Printing in Integrated Multi-Modality Imaging Approach for Management of Prosthetic Valves Infective Endocarditis”. Monaldi Archives for Chest Disease 93 (4). https://doi.org/10.4081/monaldi.2022.2479.

Similar Articles

<< < 6 7 8 9 10 11 

You may also start an advanced similarity search for this article.