Real-world effectiveness and safety of handheld ultrasound in pleural procedures

Submitted: March 15, 2024
Accepted: August 30, 2024
Published: October 3, 2024
Abstract Views: 171
PDF_EARLY VIEW: 61
Publisher's note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Authors

The use of ultrasound for pleural procedures is associated with a decreased risk of complications. Handheld ultrasounds allow for easier evaluation of the pleural space. Limited data exists for the use of such devices for pleural procedures. The primary objective of our study was to assess the effectiveness and safety of handheld ultrasound for pleural procedures. We performed a prospective observational study, including all consecutive patients who underwent pleural procedures using the handheld ultrasound between September 2021 and November 2023. A total of 332 pleural procedures were attempted with handheld ultrasound, of which 329 pleural procedures (99.1%) were successfully performed. The median volume of fluid drained was 500 (interquartile range: 300-800). Thoracentesis was performed in 127 patients (38.5%), tube thoracostomy in 179 patients (54.4%), and medical thoracoscopy in 23 patients (7.0%). Exudative pleural effusions were found in 264 patients (80.0%), of which 152 (46.2%) were determined to be due to infectious etiologies. A total of 4 (1.2%) patients had a complication due to the procedure. 2 patients (0.6%) had a pneumothorax, while 2 patients (0.6%) developed a hemothorax. A total of 101 patients had either low platelets (<50×109/L) or use of anti-platelet or anti-coagulant drugs. 128 patients (38.8%) were on positive pressure support during the pleural procedure. Our study shows that handheld ultrasounds are effective and safe for pleural procedures, including cases with septated pleural effusions and patients on anti-platelet or anti-coagulant drugs.

Dimensions

Altmetric

PlumX Metrics

Downloads

Download data is not yet available.

Citations

Light RW. Pleural effusions. Med Clin North Am 2011;95:1055-70. DOI: https://doi.org/10.1016/j.mcna.2011.08.005
Taghizadeh N, Fortin M, Tremblay A. US Hospitalizations for malignant pleural effusions: data from the 2012 national inpatient sample. Chest 2017;151:845-54. DOI: https://doi.org/10.1016/j.chest.2016.11.010
Jones PW, Moyers JP, Rogers JT, et al. Ultrasound-guided thoracentesis: is it a safer method? Chest 2003;123:418-23. DOI: https://doi.org/10.1378/chest.123.2.418
Cavanna L, Mordenti P, Berte R, et al. Ultrasound guidance reduces pneumothorax rate and improves safety of thoracentesis in malignant pleural effusion: report on 445 consecutive patients with advanced cancer. World J Surg Oncol 2014;12:139. DOI: https://doi.org/10.1186/1477-7819-12-139
Barnes TW, Morgenthaler TI, Olson EJ, et al. Sonographically guided thoracentesis and rate of pneumothorax. J Clin Ultrasound 2005;33:442-6. DOI: https://doi.org/10.1002/jcu.20163
Muruganandan S, Azzopardi M, Thomas R, et al. The pleural effusion and symptom evaluation (PLEASE) study of breathlessness in patients with a symptomatic pleural effusion. Eur Respir J 2020;55:1900980. DOI: https://doi.org/10.1183/13993003.00980-2019
Qureshi NR, Rahman NM, Gleeson FV. Thoracic ultrasound in the diagnosis of malignant pleural effusion. Thorax 2009;64:139-43. DOI: https://doi.org/10.1136/thx.2008.100545
Gordon CE, Feller-Kopman D, Balk EM, Smetana GW. Pneumothorax following thoracentesis: a systematic review and meta-analysis. Arch Intern Med 2010;170:332-9. DOI: https://doi.org/10.1001/archinternmed.2009.548
Ault MJ, Rosen BT, Scher J, et al. Thoracentesis outcomes: a 12-year experience. Thorax 2015;70:127-32. DOI: https://doi.org/10.1136/thoraxjnl-2014-206114
Cantey EP, Walter JM, Corbridge T, Barsuk JH. Complications of thoracentesis: incidence, risk factors, and strategies for prevention. Curr Opin Pulm Med 2016;22:378-85. DOI: https://doi.org/10.1097/MCP.0000000000000285
Dangers L, Giovannelli J, Mangiapan G, et al. Antiplatelet drugs and risk of bleeding after bedside pleural procedures: a national multicenter cohort study. Chest 2021;159:1621-9. DOI: https://doi.org/10.1016/j.chest.2020.10.092
Dammert P, Pratter M, Boujaoude Z. Safety of ultrasound-guided small-bore chest tube insertion in patients on clopidogrel. J Bronchology Interv Pulmonol 2013;20:16-20. DOI: https://doi.org/10.1097/LBR.0b013e31828194f9
Henning RJ. Handheld ultrasound as an adjunct to physical examination in the diagnosis of cardiopulmonary disease. Future Cardiol 2022;18:585-600. DOI: https://doi.org/10.2217/fca-2021-0142
Moore CL, Wang J, Battisti AJ, et al. Interobserver agreement and correlation of an automated algorithm for B-line identification and quantification with expert sonologist review in a handheld ultrasound device. J Ultrasound Med 2022;41:2487-95. DOI: https://doi.org/10.1002/jum.15935
Newhouse SM, Effing TW, Dougherty BD, et al. Is Bigger really better? Comparison of ultraportable handheld ultrasound with standard point-of-care ultrasound for evaluating safe site identification and image quality prior to pleurocentesis. Respiration 2020;99:325-32. DOI: https://doi.org/10.1159/000505698
Haji-Hassan M, Lenghel LM, Bolboaca SD. Hand-held ultrasound of the lung: a systematic review. Diagnostics 2021;11:1381. DOI: https://doi.org/10.3390/diagnostics11081381

Ethics Approval

The study protocol and informed consent waiver were approved by the Institutional Review Board of Aga Khan University (2023-8600-24701).

How to Cite

Alavi, Musaib, Waris Ali, Alaeddin Sagar, Majid Shafiq, Muhammad Azhar, Akbar S. Ali, and Moiz Salahuddin. 2024. “Real-World Effectiveness and Safety of Handheld Ultrasound in Pleural Procedures”. Monaldi Archives for Chest Disease, October. https://doi.org/10.4081/monaldi.2024.2992.

Similar Articles

<< < 27 28 29 30 31 32 33 34 35 36 > >> 

You may also start an advanced similarity search for this article.