What’s the best assessment of preload after cardiac surgery?

Submitted: February 17, 2016
Accepted: February 17, 2016
Published: March 30, 2005
Abstract Views: 566
PDF: 419
Publisher's note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Authors

Objective: The assessment of the role of transesophageal echocardiography and invasive tests with pulmonary modified catheter to monitor the preload indexes in patients in intensive- care-unit after cardiac coronary surgery. Materials and Methods: Between January and December 2004 24 patients (14 male, 10 female) with coronary artery disease were prospectively enrolled for preload assessment during off-pump myocardial revascularization. Pulmonary Capillary Wedge Pressure (PCWP), Left Ventricular End Diastolic Indexed Area (LVEDAI), Δ Aortic Velocity (ΔVAo), Right Ventricular End Diastolic Volume (RVEDVI) as preload indexes were evaluated. Transesophageal echocardiography and pulmonary modified catheter monitoring were performed during the preoperative period at T1 and after fluid infusion (T2). Patients were considered Responders (R) or No Responders (NR) if the Stroke Volume Index increase at T2 was >20% with respect to T1. Results: Mean T1 PCWP was similar in both groups (12.8±2.2 in R vs. 11.4±3 mmHg in NR; p=NS) and mean increase of PCWP at T2 was similar in both groups (1.5±0.3% in R vs. 1.2±3% in NR; p=NS). Mean T1 RVEDVI was similar in both groups (97.33±34 in R vs. 101±21 ml/m2 in NR; p=NS); T2 RVEDVI was similar in R and NR Groups (122.11±49 vs. 138.54±30 ml/m2; p=NS); mean T1 and T2 LVEDAI was similar in R and NR (11.2±3.5 vs. 10.2±2.3 at T1 and 14.04±3.35 vs. 14.67±2.1 cm2/m2 at T2 respectively; p=NS). Higher mean value of T1 ΔVAo (20±7% in R vs. 10±2% in NR; p=0.006) were recorded while similar mean value of T2 ΔVAo were observed (11±3% in R vs. 5±2% in NR; p=0.743). Correlation index between T1 and T2 ΔVAo (R=0.82) in R was significant (p=0.0002), while correlation index between T1 and T2 ΔVAo (R=0.11) in NR was not significant. Conclusions: Our study showed in patients soon after coronary cardiac surgery ΔVAo is the only predictor of “fluid responsiveness†and of ventricular compliance.

Dimensions

Altmetric

PlumX Metrics

Downloads

Download data is not yet available.

Citations

How to Cite

Piccirillo, Maria Rosario, Armando Natale, Giovanni Trosino, Marianna Sebastopoli, Giovanni Vivona, Giovanni De Martino, Gennaro Ismeno, Luigi Piazza, and Luigi Belloni. 2005. “What’s the Best Assessment of Preload After Cardiac Surgery?”. Monaldi Archives for Chest Disease 64 (1). https://doi.org/10.4081/monaldi.2005.606.

Similar Articles

<< < 19 20 21 22 23 24 25 26 27 28 > >> 

You may also start an advanced similarity search for this article.